Download Manual on Flash Point Standards and Their Use: Methods and by Harry A. Wray, American Society for Testing and Materials PDF

By Harry A. Wray, American Society for Testing and Materials

Show description

Read or Download Manual on Flash Point Standards and Their Use: Methods and Regulations (Astm Manual Series) PDF

Best technology books

Humans 3.0: The Upgrading of the Species

Lifestyles for early people wasn't effortless. they might were capable of stroll on ft and create instruments four million years in the past, yet they couldn't keep in mind or converse. thankfully, humans obtained smarter, and issues obtained greater. They remembered on-the-spot ideas and shared the precious details in their studies.

Central American Wars 1959 - 89

On the grounds that Fidel Castro's victory in Cuba in January 1959 the U.S. have been involved that any swap of presidency in a important American kingdom are not bring in an analogous Soviet-backed communist regime; and to avoid this it has built quite a number responses, from direct army intervention, via help of neighborhood armies, to diplomatic isolation and fiscal blockade.

Crash course in electronics technology

Mixed with the 2 different Crash path books, electronic know-how and Microprocessor know-how, this publication kinds a whole path in electronics and microcomputer expertise acceptable for technical faculties, commercial education, and hobbyists. Crash direction in Electronics know-how teaches the fundamentals of electronics, elements, and circuits in an easy-to-understand structure.

Additional resources for Manual on Flash Point Standards and Their Use: Methods and Regulations (Astm Manual Series)

Example text

0015 at 20/20'C as max. 2 Boiling Range—2*C max from start to dry point, determined by means of a calibrated pycnometer. 8'C as Method D 1078. The range shall include the boiling point of determined by Test Method D 1078. 35°C). 2 % as determined by Test Method D 1364. The AmerkxinSoclefy for Testing mid Materials taltes no positk»irespe

5 mm) in diameter and the orifice

1 —The spring clamp holding the thermometer part may be retraced by a set-screw facing out away from the bath as shown in Fig. 1. This may make it easier and safer to extinguish the fire after the fire point has been reached. 3 Glass Test Cup (Fig. l), of molded clear glass, annealed, heat-resistant, and free from surface defects. Al. 4 Leveling Device, or gage, for proper adjustment of the liquid in the cup (Fig. 2) made of polished aluminum or stainless steel Vb in. 125 in. 003 in. 08 mm) below the top edge or rim of the cup.

Download PDF sample

Rated 4.07 of 5 – based on 38 votes